Can optimal marker weightings improve thoracohumeral kinematics accuracy?
Gymnastik- och idrottshögskolan, GIH, Institutionen för idrotts- och hälsovetenskap, Laboratoriet för biomekanik och motorisk kontroll (BMC).ORCID-id: 0000-0002-1210-6449
2015 (engelsk)Inngår i: Journal of Biomechanics, ISSN 0021-9290, E-ISSN 1873-2380, Vol. 48, nr 10, s. 2019-2025Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Local and global optimization algorithms have been developed to estimate joint kinematics to reducing soft movement artifact (STA). Such algorithms can include weightings to account for different STA occur at each marker. The objective was to quantify the benefit of optimal weighting and determine if optimal marker weightings can improve humerus kinematics accuracy. A pin with five reflective markers was inserted into the humerus of four subjects. Seven markers were put on the skin of the arm. Subjects performed 38 different tasks including arm elevation, rotation, daily-living tasks, and sport activities. In each movement, mean and peak errors in skin- vs. pins-orientation were reported. Then, optimal marker weightings were found to best match skin- and pin-based orientation. Without weighting, the error of the arm orientation ranged from 1.9° to 17.9°. With weighting, 100% of the trials were improved and the average error was halved. The mid-arm markers weights were close to 0 for three subjects. Weights of a subject applied to the others for a given movement, and weights of a movement applied to others for a given subject did not systematically increased accuracy of arm orientation. Without weighting, a redundant set of marker and least square algorithm improved accuracy to estimate arm orientation compared to data of the literature using electromagnetic sensor. Weightings were subject- and movement-specific, which reinforces that STA are subject- and movement-specific. However, markers on the deltoid insertion and on lateral and medial epicondyles may be preferred if a limited number of markers is used.

sted, utgiver, år, opplag, sider
2015. Vol. 48, nr 10, s. 2019-2025
HSV kategori
Forskningsprogram
Medicin/Teknik
Identifikatorer
URN: urn:nbn:se:gih:diva-3815DOI: 10.1016/j.jbiomech.2015.03.023PubMedID: 25935687OAI: oai:DiVA.org:gih-3815DiVA, id: diva2:812528
Tilgjengelig fra: 2015-05-19 Laget: 2015-05-19 Sist oppdatert: 2017-12-04bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Arndt, Anton

Søk i DiVA

Av forfatter/redaktør
Arndt, Anton
Av organisasjonen
I samme tidsskrift
Journal of Biomechanics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 258 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf