Gymnastik- och idrottshögskolan, GIH

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Inter-Rater Reliability of Clinical Testing for Laxity After Knee Arthroplasty
Department of Neuromedicine and Movement Science, Center for Elite Sports Research, Norwegian University of Science and Technology, Trondheim, Norway.ORCID iD: 0000-0003-0404-1072
Show others and affiliations
2022 (English)In: The Journal of Arthroplasty, ISSN 0883-5403, E-ISSN 1532-8406, Vol. 37, no 7Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: The clinical examination for laxity has been considered a mainstay in evaluation of the painful knee arthroplasty, especially for the diagnosis of instability. More than 10 mm of anterior-posterior (AP) translation in flexion has been described as important in the diagnosis of flexion instability. The inter-observer reliability of varus/valgus and AP laxity testing has not been tested. METHODS: Ten subjects with prior to total knee arthroplasty (TKA) were examined by 4 fellowship-trained orthopedic knee arthroplasty surgeons. Each surgeon evaluated each subject in random order and was blinded to the results of the other surgeons. Each surgeon performed an anterior drawer test at 30 and 90 degrees of flexion and graded the instability as 0-5 mm, 5-10 mm or >10 mm. Varus-valgus testing was also graded. Motion capture was used during the examination to determine the joint position and estimate joint reaction force during the examination. RESULTS: Inter-rater reliability (IRR) was poor at 30 and 90 degrees for both the subjective rater score and the measured AP laxity in flexion (k = 018-0.22). Varus-valgus testing similarly had poor reliability. Force applied by the rater also had poor IRR. CONCLUSION: Clinical testing of knee laxity after TKA has poor reliability between surgeons using motion analysis. It is unclear if this is from differences in examiner technique or from differences in pain or quadriceps function of the subjects. Instability after TKA should not be diagnosed strictly by clinical testing and should involve a complete clinical assessment of the patient.

Place, publisher, year, edition, pages
2022. Vol. 37, no 7
Keywords [en]
*Arthroplasty, Replacement, Knee/adverse effects/methods Biomechanical Phenomena Humans *Joint Instability/surgery Knee Joint/surgery Pain/surgery Range of Motion, Articular Reproducibility of Results clinical examination flexion instability knee laxity painful TKA physical examination
National Category
Orthopaedics
Identifiers
URN: urn:nbn:se:gih:diva-9097DOI: 10.1016/j.arth.2022.03.044OAI: oai:DiVA.org:gih-9097DiVA, id: diva2:2039377
Available from: 2026-02-17 Created: 2026-02-17 Last updated: 2026-02-17

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubmed

Authority records

Severin, Cecilia

Search in DiVA

By author/editor
Severin, Cecilia
In the same journal
The Journal of Arthroplasty
Orthopaedics

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 43 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf