Gymnastik- och idrottshögskolan, GIH

Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Bilateral electromyogram response latency following platform perturbation in unilateral transtibial prosthesis users: influence of weight distribution and limb position.
Gymnastik- och idrottshögskolan, GIH, Institutionen för idrotts- och hälsovetenskap, Laboratoriet för biomekanik och motorisk kontroll (BMC).
2013 (Engelska)Ingår i: Journal of rehabilitation research and development, ISSN 0748-7711, E-ISSN 1938-1352, Vol. 50, nr 4, s. 531-44Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Appropriate muscular response following an external perturbation is essential in preventing falls. Transtibial prosthesis users lack a foot-ankle complex and associated sensorimotor structures on the side with the prosthesis. The effect of this lack on rapid responses of the lower limb to external surface perturbations is unknown. The aim of the present study was to compare electromyogram (EMG) response latencies of otherwise healthy, unilateral, transtibial prosthesis users (n = 23, mean +/- standard deviation [SD] age = 48 +/- 14 yr) and a matched control group (n = 23, mean +/- SD age = 48 +/- 13 yr) following sudden support-surface rotations in the pitch plane (toes-up and toes-down). Perturbations were elicited in various weight-bearing and limb-perturbed conditions. The results indicated that transtibial prosthesis users have delayed responses of multiple muscles of the lower limb following perturbation, both in the intact and residual limbs. Weight-bearing had no influence on the response latency in the residual limb, but did on the intact limb. Which limb received the perturbation was found to influence the muscular response, with the intact limb showing a significantly delayed response when the perturbation was received only on the side with a prosthesis. These delayed responses may represent an increased risk of falling for individuals who use transtibial prostheses.

Ort, förlag, år, upplaga, sidor
2013. Vol. 50, nr 4, s. 531-44
Nationell ämneskategori
Medicin och hälsovetenskap
Forskningsämne
Medicin/Teknik
Identifikatorer
URN: urn:nbn:se:gih:diva-3125PubMedID: 23934873OAI: oai:DiVA.org:gih-3125DiVA, id: diva2:677465
Tillgänglig från: 2013-12-09 Skapad: 2013-12-09 Senast uppdaterad: 2025-09-16Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

PubMed

Person

Nolan, Lee

Sök vidare i DiVA

Av författaren/redaktören
Nolan, Lee
Av organisationen
Laboratoriet för biomekanik och motorisk kontroll (BMC)
I samma tidskrift
Journal of rehabilitation research and development
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetricpoäng

pubmed
urn-nbn
Totalt: 343 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf