Can optimal marker weightings improve thoracohumeral kinematics accuracy?
Swedish School of Sport and Health Sciences, GIH, Department of Sport and Health Sciences, Laboratory for Biomechanics and Motor Control.ORCID iD: 0000-0002-1210-6449
2015 (English)In: Journal of Biomechanics, ISSN 0021-9290, E-ISSN 1873-2380, Vol. 48, no 10, p. 2019-2025Article in journal (Refereed) Published
Abstract [en]

Local and global optimization algorithms have been developed to estimate joint kinematics to reducing soft movement artifact (STA). Such algorithms can include weightings to account for different STA occur at each marker. The objective was to quantify the benefit of optimal weighting and determine if optimal marker weightings can improve humerus kinematics accuracy. A pin with five reflective markers was inserted into the humerus of four subjects. Seven markers were put on the skin of the arm. Subjects performed 38 different tasks including arm elevation, rotation, daily-living tasks, and sport activities. In each movement, mean and peak errors in skin- vs. pins-orientation were reported. Then, optimal marker weightings were found to best match skin- and pin-based orientation. Without weighting, the error of the arm orientation ranged from 1.9° to 17.9°. With weighting, 100% of the trials were improved and the average error was halved. The mid-arm markers weights were close to 0 for three subjects. Weights of a subject applied to the others for a given movement, and weights of a movement applied to others for a given subject did not systematically increased accuracy of arm orientation. Without weighting, a redundant set of marker and least square algorithm improved accuracy to estimate arm orientation compared to data of the literature using electromagnetic sensor. Weightings were subject- and movement-specific, which reinforces that STA are subject- and movement-specific. However, markers on the deltoid insertion and on lateral and medial epicondyles may be preferred if a limited number of markers is used.

Place, publisher, year, edition, pages
2015. Vol. 48, no 10, p. 2019-2025
National Category
Medical and Health Sciences
Research subject
Medicine/Technology
Identifiers
URN: urn:nbn:se:gih:diva-3815DOI: 10.1016/j.jbiomech.2015.03.023ISI: 000358459800046PubMedID: 25935687OAI: oai:DiVA.org:gih-3815DiVA, id: diva2:812528
Available from: 2015-05-19 Created: 2015-05-19 Last updated: 2021-04-13Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Arndt, Anton

Search in DiVA

By author/editor
Arndt, Anton
By organisation
Laboratory for Biomechanics and Motor Control
In the same journal
Journal of Biomechanics
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 351 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf