A new dynamometer measuring concentric and eccentric muscle strength in accelerated, decelerated, or isokinetic movements
Swedish School of Sport and Health Sciences, GIH, Department of Sport and Health Sciences, Björn Ekblom's research group.
Show others and affiliations
1988 (English)In: European Journal of Applied Physiology and Occupational Physiology, ISSN 0301-5548, E-ISSN 1432-1025, Vol. 57, p. 526-530Article in journal (Refereed) Published
Abstract [en]

A new computerized dynamometer (the SPARK System) is described. The system can measure concentric and eccentric muscle strength (torque) during linear or nonlinear acceleration or deceleration, isokinetic movements up to 400 degrees.s-1, and isometric torque. Studies were performed to assess: I. validity and reproducibility of torque measurements; II. control of lever arm position; III. control of different velocity patterns; IV. control of velocity during subject testing; and, V. intra-individual reproducibility. No significant difference was found between torque values computed by the system and known torque values (p greater than 0.05). No difference was present between programmed and external measurement of the lever arm position. Accelerating, decelerating and isokinetic velocity patterns were highly reproducible, with differences in elapsed time among 10 trials being never greater than 0.001 s. Velocity during concentric and eccentric isokinetic quadriceps contractions at 30 degrees.s-1, 120 degrees.s-1 and 270 degrees.s-1 never varied by more than 3 degrees.s-1 among subjects (N = 21). Over three days of testing, the overall error for concentric and eccentric quadriceps contraction peak torque values for 5 angular velocities between 30 degrees.s-1 and 270 degrees.s-1 ranged from 5.8% to 9.0% and 5.8% to 9.6% respectively (N = 25). The results indicate that the SPARK System provides valid and reproducible torque measurements and strict control of velocity. In addition, the intra-individual error is in accordance with those reported for other similar devices.

Place, publisher, year, edition, pages
1988. Vol. 57, p. 526-530
National Category
Physiology
Identifiers
URN: urn:nbn:se:gih:diva-406OAI: oai:DiVA.org:gih-406DiVA, id: diva2:771
Available from: 2008-06-04 Created: 2008-06-04 Last updated: 2018-01-11Bibliographically approved

Open Access in DiVA

No full text in DiVA

Authority records

Seger, JanEkblom, Björn

Search in DiVA

By author/editor
Seger, JanEkblom, Björn
By organisation
Björn Ekblom's research group
In the same journal
European Journal of Applied Physiology and Occupational Physiology
Physiology

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 333 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf