Gymnastik- och idrottshögskolan, GIH

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
9+ screening batteri: en reliabilitetsstudie av testbatteriet genomfört på unga fotbollsspelande flickor
Swedish School of Sport and Health Sciences, GIH, Department of Sport and Health Sciences.
2014 (Swedish)Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE creditsStudent thesisAlternative title
9+ screening battery : A reliability study of the test battery among young female soccer players (English)
Abstract [sv]

Syfte

Syftet med studien var att undersöka inter- och intrabedömarreliabiliteten för rörelseanalysen ”9+ screening batteri” hos en grupp unga fotbollsspelande flickor med avseende totala bedömningen av rörelseutförandet.

 

Metod

Tolv friska fotbollsaktiva flickor (13-14 år) deltog i studien. Testerna genomfördes vid två tillfällen med sju dagars mellanrum. Screeningbatteriet bestod av elva funktionella test samt tre tilläggstest. Utförandet bedömdes av sex sjukgymnaster som alla hade liten vana av att använda testbatteriet.

 

Resultat

Gruppen hade ett medelvärde på 17.2 ± 1.3 (95 % CI; 14.4–19.9) vid testtillfälle 1 och 17.4 ± 1.8 (95 % CI; 13.4–21.5) vid testtillfälle 2 av totalt 33 poäng. Därmed fanns det ingen deltagare som nådde upp till 22 poäng (67 %) som är den förutbestämda gräns som föreslagits indikera ökad risk för skada. Det fanns ingen signifikant skillnad (p = 0.54) för interbedömarreliabiliteten mellan testtillfälle 1 och 2 gällande den totala poängsumman för hela screeningbatteriet. Däremot fanns en signifikant skillnad mellan sjukgymnasterna (p = 0.002) där bedömare 1 (p = 0.007) och bedömare 2 (p = 0.003) angav högre värden i jämförelse med bedömare 4. ICC för interbedömarreliabilitet för testtillfälle 1 och 2 var 0.68. Medelvärdet för ICC för alla sjukgymnaster för intrabedömarreliabilitet var 0.60. ICC varierade mellan 0.43-0.67 (p = 0.16-0.65).

 

Slutsats

Denna studie visar att 9 + screening batteri är måttligt reliabelt vid screening av unga fotbollsspelande flickor både för inter- och intrabedömarreliabilitet när det gäller hela testbatteriet. Den låga totalsumman hos gruppen visar även att det är ytterst viktigt att fånga upp de atleter ur denna population som genom rörelseanalys upptäcks ha en ökad risk för skada. Genom preventiva åtgärder kan eventuella skador förhindras.

Abstract [en]

Aim

The aim of the study was to determine inter- and intra-rater reliability of the total score from the functional movement screening test - 9+ screening battery, among a group young female soccer players.

 

Method

Twelve healthy female soccer players (13-14 years) participated in the study. The tests were conducted on two occasions separated by seven days. The screening battery included eleven functional movement tests and three clearing exams. The performance was evaluated by six physical therapists with little experience in this specific test battery.

 

Results

The mean score of the group was 17.2 ± 1.3 (95 % CI; 14.4–19.9) for test occasion 1 and 17.4 ± 1.8 (95 % CI; 13.4–21.5) for test occasion 2 out of a total of 33 points. However, there were no participants that reached 22 points (67 %), i.e. the predetermined limit proposed to indicate a risk of injury. There was no significant difference (p=0.54) of the inter-rater reliability between test occasion 1 and 2 in the total score of the entire screening battery. A significant difference was observed in the scoring between the physical therapists (p = 0.002), where rater 1 (p = 0.007) and rater 2 (p = 0.003) scored higher values ​​in comparison to rater 4. Intra class correlation (ICC) for inter-rater reliability for test occasion 1 and 2 was 0.68. The mean ICC for inter-rater reliability for all physical therapists was 0.60, and ICC ranged from 0.43-0.67 (p = 0.16-0.65).

 

Conclusions

This study shows that the 9+ screening battery is moderately reliable when screening young female soccer players for both inter-and intra-rater reliability in regards to the results for the entire test battery. The low total score of the group also shows that it is extremely important to find those athletes from this population who, through functional movement analysis, are detected to have an increased risk of injury. Preventative measures may help potential injuries to be avoided.

Place, publisher, year, edition, pages
2014.
Series
Examensarbete ; 2014:73
National Category
Physiotherapy
Identifiers
URN: urn:nbn:se:gih:diva-3356OAI: oai:DiVA.org:gih-3356DiVA, id: diva2:732407
Educational program
Magisterprogrammet i idrottsvetenskap med inriktning mot idrottsmedicin
Supervisors
Examiners
Available from: 2014-07-04 Created: 2014-07-04 Last updated: 2014-07-04Bibliographically approved

Open Access in DiVA

fulltext(1193 kB)878 downloads
File information
File name FULLTEXT01.pdfFile size 1193 kBChecksum SHA-512
acca33f8fa0b050d2b698352ddd3f2dced1f870cf65626a37b79a61d1205eafb7e8b8b11e949cf0813a55176fd81f76ff0cedffe9297314b8d7414746bd411c8
Type fulltextMimetype application/pdf

By organisation
Department of Sport and Health Sciences
Physiotherapy

Search outside of DiVA

GoogleGoogle Scholar
Total: 893 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 545 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf