Reliabilty and validity of new double poling ergometer for cross-country skiers
Swedish School of Sport and Health Sciences, GIH, Department of Sport and Health Sciences, Laboratory for Biomechanics and Motor Control.ORCID iD: 0000-0002-3612-449X
2008 (English)In: Journal of Sports Sciences, ISSN 0264-0414, E-ISSN 1466-447X, Vol. 26, no 2, p. 171-179Article in journal (Refereed) Published
Abstract [en]

Thirty-eight competitive cross-country skiers were divided into three groups to assess the reliability and validity of a new double poling ergometer. Group A (n = 22) performed two maximal 60-s tests, Group B (n = 8) repeated peak oxygen uptake tests on the double poling ergometer, and Group C (n = 8) performed a maximal 6-min test on the double poling ergometer and a double poling time-trial on snow. The correlation between the power calculated at the flywheel and the power applied at the base of the poles was r = 0.99 (P < 0.05). The power at the poles was 50 – 70% higher than that at the flywheel. There was a high test – retest reliability in the two 60-s power output tests (coefficient of variation = 3.0%) and no significant difference in peak oxygen uptake in the two 6-min all-out tests (coefficient of variation = 2.4%). There was a strong correlation between the absolute (W) and relative power (W · kg−1) output in the 6-min double poling ergometer test and the double poling performance on snow (r = 0.86 and 0.89 respectively; both P < 0.05). In conclusion, our results show that the double poling ergometer has both high reliability and validity. However, the power calculated at the flywheel underestimated the total power produced and needs to be corrected for in ergonomic estimations.

Place, publisher, year, edition, pages
2008. Vol. 26, no 2, p. 171-179
National Category
Biological Sciences Medical Engineering
Research subject
Medicine/Technology
Identifiers
URN: urn:nbn:se:gih:diva-2037DOI: 10.1080/02640410701372685OAI: oai:DiVA.org:gih-2037DiVA, id: diva2:472512
Available from: 2012-01-04 Created: 2012-01-02 Last updated: 2017-12-08Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Nilsson, Johnny

Search in DiVA

By author/editor
Nilsson, Johnny
By organisation
Laboratory for Biomechanics and Motor Control
In the same journal
Journal of Sports Sciences
Biological SciencesMedical Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 459 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf