Gymnastik- och idrottshögskolan, GIH

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Microdialysis in human skeletal muscle: effects of adding a colloid to the perfusate.
Swedish School of Sport and Health Sciences, GIH, Department of Sport and Health Sciences.ORCID iD: 0000-0002-8248-0348
Swedish School of Sport and Health Sciences, GIH, Department of Sport and Health Sciences.ORCID iD: 0000-0001-8161-5610
Swedish School of Sport and Health Sciences, GIH, Department of Sport and Health Sciences.
2002 (English)In: Journal of applied physiology, ISSN 8750-7587, E-ISSN 1522-1601, Vol. 92, no 1, p. 385-93Article in journal (Refereed) Published
Abstract [en]

Microdialysis catheters (CMA-60 with a polyamide dialysis membrane; 20,000-molecular wt cutoff) were either immersed in an external medium or were inserted in the quadriceps femoris muscle of healthy subjects, using perfusate with or without dextran 70. Varying the position of the outflow tubing induced changes in hydrostatic pressure. The sample volumes were significantly smaller in catheters perfused without a colloid compared with those perfused with a colloid [11-50% (in vitro) and 8-59% (in vivo) lower than in colloid-perfused catheters with the same position of the outflow tubing]. The sample volumes were also significantly smaller when the dialysis membrane was influenced by maximal hydrostatic pressure (above position) compared with minimal hydrostatic pressure (below position) [7-38% (in vitro) and 3-46% (in vivo) lower than in catheters in the below position with the same perfusion fluid]. In vivo, glucose concentration at a perfusion flow rate of 0.33 microl/min was higher when the catheters were perfused without a colloid [18-28% higher than in colloid-perfused catheters with the same position of the outflow tubing (P < 0.001)] than with a colloid. A corresponding difference also tended to occur with lactate, glycerol, and urea. At 0.16 microl/min, the glucose concentration was the same irrespective of whether fluid loss had been counteracted by colloid inclusion or by lowering of outlet tubing. The mechanism behind the observed concentration difference is thought to be a higher effective perfusion flow rate when fluid loss is prevented at low-perfusion flows. This study shows that fluid imbalances can have important implications for microdialysis results at low-perfusion flow rates.

Place, publisher, year, edition, pages
2002. Vol. 92, no 1, p. 385-93
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:gih:diva-1062PubMedID: 11744681OAI: oai:DiVA.org:gih-1062DiVA, id: diva2:284553
Available from: 2010-01-07 Created: 2010-01-07 Last updated: 2017-12-12Bibliographically approved

Open Access in DiVA

No full text in DiVA

PubMed

Authority records

Hamrin, KerstinRosdahl, Hans

Search in DiVA

By author/editor
Hamrin, KerstinRosdahl, Hans
By organisation
Department of Sport and Health Sciences
In the same journal
Journal of applied physiology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetric score

pubmed
urn-nbn
Total: 404 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf