Gymnastik- och idrottshögskolan, GIH

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Effects of Frequency Filtering on Intensity and Noise in Accelerometer-Based Physical Activity Measurements.
University of Gothenburg.
University of Gothenburg.
Leibniz Institute for Prevention Research and epidemiology (BIPS), Bremen, Germany.
Swedish School of Sport and Health Sciences, GIH, Department of Sport and Health Sciences, Åstrand Laboratory of Work Physiology.ORCID iD: 0000-0001-6058-4982
Show others and affiliations
2019 (English)In: Sensors, E-ISSN 1424-8220, Vol. 19, no 9, article id E2186Article in journal (Refereed) Published
Abstract [en]

In objective physical activity (PA) measurements, applying wider frequency filters than the most commonly used ActiGraph (AG) filter may be beneficial when processing accelerometry data. However, the vulnerability of wider filters to noise has not been investigated previously. This study explored the effect of wider frequency filters on measurements of PA, sedentary behavior (SED), and capturing of noise. Apart from the standard AG band-pass filter (0.29-1.63 Hz), modified filters with low-pass component cutoffs at 4 Hz, 10 Hz, or removed were analyzed. Calibrations against energy expenditure were performed with lab data from children and adults to generate filter-specific intensity cut-points. Free-living accelerometer data from children and adults were processed using the different filters and intensity cut-points. There was a contribution of acceleration related to PA at frequencies up to 10 Hz. The contribution was more pronounced at moderate and vigorous PA levels, although additional acceleration also occurred at SED. The classification discrepancy between AG and the wider filters was small at SED (1-2%) but very large at the highest intensities (>90%). The present study suggests an optimal low-pass frequency filter with a cutoff at 10 Hz to include all acceleration relevant to PA with minimal effect of noise.

Place, publisher, year, edition, pages
MDPI, 2019. Vol. 19, no 9, article id E2186
Keywords [en]
ActiGraph, Axivity, I.Family, LIV-2013, adults, calibration, children
National Category
Medical Laboratory and Measurements Technologies Sport and Fitness Sciences
Research subject
Medicine/Technology
Identifiers
URN: urn:nbn:se:gih:diva-5745DOI: 10.3390/s19092186ISI: 000469766800230PubMedID: 31083538OAI: oai:DiVA.org:gih-5745DiVA, id: diva2:1316594
Projects
Mätning av det dagliga aktivitetsmönstretAvailable from: 2019-05-20 Created: 2019-05-20 Last updated: 2022-12-01

Open Access in DiVA

fulltext(2580 kB)234 downloads
File information
File name FULLTEXT01.pdfFile size 2580 kBChecksum SHA-512
8934ee0fefc3bde412862b9ac1a115f08c3e824d3f32b9ce06b6dd17496245701519c1b205136f7a06a9dfb9bf41fa24445d132ab18fb7365e8aa3045c03fa08
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Authority records

Ekblom, ÖrjanEkblom Bak, Elin

Search in DiVA

By author/editor
Ekblom, ÖrjanEkblom Bak, Elin
By organisation
Åstrand Laboratory of Work Physiology
In the same journal
Sensors
Medical Laboratory and Measurements TechnologiesSport and Fitness Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 234 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 356 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf