Gymnastik- och idrottshögskolan, GIH

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Automatic Myotendinous Junction Tracking in Ultrasound Images with Phase-Based Segmentation.
Southeast University, Nanjing, China.
Southeast University, Nanjing, China.
Karolinska Institute & Royal Institute of Technology, Stockholm.
Southeast University, Nanjing, China.
Show others and affiliations
2018 (English)In: BioMed Research International, ISSN 2314-6133, E-ISSN 2314-6141, article id 3697835Article in journal (Refereed) Published
Abstract [en]

Displacement of the myotendinous junction (MTJ) obtained by ultrasound imaging is crucial to quantify the interactive length changes of muscles and tendons for understanding the mechanics and pathological conditions of the muscle-tendon unit during motion. However, the lack of a reliable automatic measurement method restricts its application in human motion analysis. This paper presents an automated measurement of MTJ displacement using prior knowledge on tendinous tissues and MTJ, precluding the influence of nontendinous components on the estimation of MTJ displacement. It is based on the perception of tendinous features from musculoskeletal ultrasound images using Radon transform and thresholding methods, with information about the symmetric measures obtained from phase congruency. The displacement of MTJ is achieved by tracking manually marked points on tendinous tissues with the Lucas-Kanade optical flow algorithm applied over the segmented MTJ region. The performance of this method was evaluated on ultrasound images of the gastrocnemius obtained from 10 healthy subjects (26.0±2.9 years of age). Waveform similarity between the manual and automatic measurements was assessed by calculating the overall similarity with the coefficient of multiple correlation (CMC).<italic> In vivo</italic> experiments demonstrated that MTJ tracking with the proposed method (CMC = 0.97±0.02) was more consistent with the manual measurements than existing optical flow tracking methods (CMC = 0.79±0.11). This study demonstrated that the proposed method was robust to the interference of nontendinous components, resulting in a more reliable measurement of MTJ displacement, which may facilitate further research and applications related to the architectural change of muscles and tendons. [ABSTRACT FROM AUTHOR]

Place, publisher, year, edition, pages
Hindawi Limited , 2018. article id 3697835
Keywords [en]
Surgetendon Ry, Calf Muscles, Surgery, Algorithms, Automation, Correlation (Statistics), Dislocations (Anatomy), Tendons, Ultrasonic Imaging, Wave Analysis, Computer-Assisted Surgery, In Vivo Studies
National Category
Medical Laboratory and Measurements Technologies
Research subject
Medicine/Technology
Identifiers
URN: urn:nbn:se:gih:diva-5234DOI: 10.1155/2018/3697835ISI: 000427851400001PubMedID: 29750152OAI: oai:DiVA.org:gih-5234DiVA, id: diva2:1194039
Available from: 2018-03-28 Created: 2018-03-28 Last updated: 2018-10-15

Open Access in DiVA

fulltext(5019 kB)201 downloads
File information
File name FULLTEXT01.pdfFile size 5019 kBChecksum SHA-512
a396ff4c90c1db806a29ae555f4b6e0ca8e0ba2177947021c2f3d3b985ff38c403be5fc5cac8548dc530307dc4b5c41e93e39ce2103c1313a96e1bc4466f611d
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Authority records

Tarassova, OlgaArndt, Anton

Search in DiVA

By author/editor
Tarassova, OlgaArndt, Anton
By organisation
Laboratory for Biomechanics and Motor Control
In the same journal
BioMed Research International
Medical Laboratory and Measurements Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 201 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 483 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf