Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Re-examination of accelerometer data processing and calibration for the assessment of physical activity intensity.
University of Gothenburg.
University of Gothenburg.
University of Gothenburg.
Western Norway University of Applied Sciences, Campus Sogndal, Norway..
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Scandinavian Journal of Medicine and Science in Sports, ISSN 0905-7188, E-ISSN 1600-0838, Vol. 29, nr 10, s. 1442-1452Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

This review reexamines use of accelerometer and oxygen uptake data for assessment of activity intensity. Accelerometers capture mechanical work, while oxygen uptake captures the energy cost of this work. Frequency filtering needs to be considered when processing acceleration data. A too restrictive filter attenuates the acceleration signal for walking and, to a higher degree, for running. This measurement error affects shorter (children) more than taller (adults) individuals due to their higher movement frequency. Less restrictive filtering includes more movement related signals and provide measures that better capture mechanical work, but may include more noise. An optimal filter cut-point is determined where most relevant acceleration signals are included. Further, accelerometer placement affects what part of mechanical work being captured. While the waist placement captures total mechanical work and therefore contributes to measures of activity intensity equivalent by age and stature, the thigh and wrist placements capture more internal work and do not provide equivalent measures. Value calibration of accelerometer measures is usually performed using measured oxygen uptake with the metabolic equivalent of task (MET) as reference measure of activity intensity. However, the use of MET is not stringent and is not a measure of activity intensity equivalent by age and stature. A candidate measure is the mass-specific net oxygen uptake, VO2 net (VO2 tot - VO2 stand). To improve measurement of physical activity intensity using accelerometers, research developments are suggested concerning processing of accelerometer data, use of energy expenditure as reference for activity intensity, and calibration procedure with absolute versus relative intensity. This article is protected by copyright. All rights reserved.

Ort, förlag, år, upplaga, sidor
John Wiley & Sons, 2019. Vol. 29, nr 10, s. 1442-1452
Nyckelord [en]
Acceleration, counts, energy expenditure, frequency filtering, mechanical work
Nationell ämneskategori
Medicinsk laboratorie- och mätteknik Idrottsvetenskap
Forskningsämne
Medicin/Teknik
Identifikatorer
URN: urn:nbn:se:gih:diva-5746DOI: 10.1111/sms.13470ISI: 000488616400001PubMedID: 31102474OAI: oai:DiVA.org:gih-5746DiVA, id: diva2:1316601
Tillgänglig från: 2019-05-20 Skapad: 2019-05-20 Senast uppdaterad: 2019-10-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Ekblom, Örjan

Sök vidare i DiVA

Av författaren/redaktören
Ekblom, Örjan
Av organisationen
Åstrandlaboratoriet
I samma tidskrift
Scandinavian Journal of Medicine and Science in Sports
Medicinsk laboratorie- och mätteknikIdrottsvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 177 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf