Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Evaluation of physiological workload assessment methods using heart rate and accelerometry for a smart wearable system.
KTH Royal Institute of Technology.
KTH Royal Institute of Technology.
KTH Royal Institute of Technology.
Karolinska Institutet.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Ergonomics, ISSN 0014-0139, E-ISSN 1366-5847, Vol. 62, nr 5, s. 694-705Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Work metabolism (WM) can be accurately estimated by oxygen consumption (VO2), which is commonly assessed by heart rate (HR) in field studies. However, the VO2-HR relationship is influenced by individual capacity and activity characteristics. The purpose of this study was to evaluate three models for estimating WM compared with indirect calorimetry, during simulated work activities. The techniques were: the HR-Flex model; HR branched model, combining HR with hip-worn accelerometers (ACC); and HR + arm-leg ACC model, combining HR with wrist- and thigh-worn ACC. Twelve participants performed five simulated work activities and three submaximal tests. The HR + arm-leg ACC model had the overall best performance with limits of agreement (LoA) of -3.94 and 2.00 mL/min/kg, while the HR-Flex model had -5.01 and 5.36 mL/min/kg and the branched model, -6.71 and 1.52 mL/min/kg. In conclusion, the HR + arm-leg ACC model should, when feasible, be preferred in wearable systems for WM estimation. Practitioner Summary: Work with high energy demand can impair employees' health and life quality. Three models were evaluated for estimating work metabolism during simulated tasks. The model combining heart rate, wrist- and thigh-worn accelerometers showed the best accuracy. This is, when feasible, suggested for wearable systems to assess work metabolism.

Ort, förlag, år, upplaga, sidor
Taylor & Francis, 2019. Vol. 62, nr 5, s. 694-705
Nyckelord [en]
Heart rate, estimation models, motion sensing, risk assessment, wearable sensors, work metabolism
Nationell ämneskategori
Arbetsmedicin och miljömedicin
Forskningsämne
Medicin/Teknik
Identifikatorer
URN: urn:nbn:se:gih:diva-5702DOI: 10.1080/00140139.2019.1566579PubMedID: 30806164OAI: oai:DiVA.org:gih-5702DiVA, id: diva2:1302433
Tillgänglig från: 2019-04-04 Skapad: 2019-04-04 Senast uppdaterad: 2019-11-06Bibliografiskt granskad

Open Access i DiVA

fulltext(2356 kB)52 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2356 kBChecksumma SHA-512
5f7a725ca6accf37bb7cc9470cea6156a2ab8f453ab6882e3aeacf5fa73732736e9b5fea214cf31f9a597b2136d18670639cf4f1941e0097aa293766e7db1c4a
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Ekblom, Örjan

Sök vidare i DiVA

Av författaren/redaktören
Ekblom, Örjan
Av organisationen
Björn Ekbloms forskningsgrupp
I samma tidskrift
Ergonomics
Arbetsmedicin och miljömedicin

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 52 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 105 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf