Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Automatic Myotendinous Junction Tracking in Ultrasound Images with Phase-Based Segmentation.
Southeast University, Nanjing, China.
Southeast University, Nanjing, China.
Karolinska Institute & Royal Institute of Technology, Stockholm.
Southeast University, Nanjing, China.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: BioMed Research International, ISSN 2314-6133, E-ISSN 2314-6141, artikel-id 3697835Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Displacement of the myotendinous junction (MTJ) obtained by ultrasound imaging is crucial to quantify the interactive length changes of muscles and tendons for understanding the mechanics and pathological conditions of the muscle-tendon unit during motion. However, the lack of a reliable automatic measurement method restricts its application in human motion analysis. This paper presents an automated measurement of MTJ displacement using prior knowledge on tendinous tissues and MTJ, precluding the influence of nontendinous components on the estimation of MTJ displacement. It is based on the perception of tendinous features from musculoskeletal ultrasound images using Radon transform and thresholding methods, with information about the symmetric measures obtained from phase congruency. The displacement of MTJ is achieved by tracking manually marked points on tendinous tissues with the Lucas-Kanade optical flow algorithm applied over the segmented MTJ region. The performance of this method was evaluated on ultrasound images of the gastrocnemius obtained from 10 healthy subjects (26.0±2.9 years of age). Waveform similarity between the manual and automatic measurements was assessed by calculating the overall similarity with the coefficient of multiple correlation (CMC).<italic> In vivo</italic> experiments demonstrated that MTJ tracking with the proposed method (CMC = 0.97±0.02) was more consistent with the manual measurements than existing optical flow tracking methods (CMC = 0.79±0.11). This study demonstrated that the proposed method was robust to the interference of nontendinous components, resulting in a more reliable measurement of MTJ displacement, which may facilitate further research and applications related to the architectural change of muscles and tendons. [ABSTRACT FROM AUTHOR]

Ort, förlag, år, upplaga, sidor
Hindawi Limited , 2018. artikel-id 3697835
Nyckelord [en]
Surgetendon Ry, Calf Muscles, Surgery, Algorithms, Automation, Correlation (Statistics), Dislocations (Anatomy), Tendons, Ultrasonic Imaging, Wave Analysis, Computer-Assisted Surgery, In Vivo Studies
Nationell ämneskategori
Medicinsk laboratorie- och mätteknik
Forskningsämne
Medicin/Teknik
Identifikatorer
URN: urn:nbn:se:gih:diva-5234DOI: 10.1155/2018/3697835ISI: 000427851400001PubMedID: 29750152OAI: oai:DiVA.org:gih-5234DiVA, id: diva2:1194039
Tillgänglig från: 2018-03-28 Skapad: 2018-03-28 Senast uppdaterad: 2018-10-15

Open Access i DiVA

fulltext(5019 kB)21 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 5019 kBChecksumma SHA-512
a396ff4c90c1db806a29ae555f4b6e0ca8e0ba2177947021c2f3d3b985ff38c403be5fc5cac8548dc530307dc4b5c41e93e39ce2103c1313a96e1bc4466f611d
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Tarassova, OlgaArndt, Anton

Sök vidare i DiVA

Av författaren/redaktören
Tarassova, OlgaArndt, Anton
Av organisationen
Laboratoriet för biomekanik och motorisk kontroll (BMC)
I samma tidskrift
BioMed Research International
Medicinsk laboratorie- och mätteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 21 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 190 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf