Electrically evoked eccentric and concentric torque-velocity relationships in human knee extensor muscles.
Gymnastik- och idrottshögskolan, GIH, Institutionen för idrotts- och hälsovetenskap.
Gymnastik- och idrottshögskolan, GIH, Institutionen för idrotts- och hälsovetenskap, Laboratoriet för biomekanik och motorisk kontroll (BMC).
2000 (engelsk)Inngår i: Acta Physiologica Scandinavica, ISSN 0001-6772, E-ISSN 1365-201X, Vol. 169, s. 63-69Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The torque-velocity relationship, obtained during in situ conditions in humans, demonstrates a levelling-off of eccentric torque output at the isometric torque level, at least for knee extensor actions. In contrast, the in vitro force-velocity relationship for animal muscle preparations is characterized by a sharp rise in eccentric force from isometric maximum. A force-regulating 'protective' mechanism has been suggested during maximal voluntary high-tension eccentric muscle actions. To investigate this phenomenon, maximal voluntary and three different levels of submaximal, electrically induced torques were compared during isometric and low velocity (10, 20 and 30 degrees s-1) isokinetic eccentric and concentric knee extensor actions in 10 healthy, moderately trained subjects. Eccentric torque was higher than isometric during electrically evoked, but not during maximal voluntary muscle actions. In contrast, concentric torque was significantly lower than isometric for both maximal voluntary and submaximal, electrically evoked conditions. Comparisons of normalized torques (isometric value under each condition set to 100%) demonstrated that the maximal voluntary eccentric torque had to be increased by 20%, and the isometric by 10% in order for the maximal voluntary torque-velocity curve to coincide with the electrically stimulated submaximal ones. These results support the notion that a tension-regulating mechanism is present primarily during eccentric maximal voluntary knee extensor actions.

sted, utgiver, år, opplag, sider
2000. Vol. 169, s. 63-69
HSV kategori
Identifikatorer
URN: urn:nbn:se:gih:diva-403OAI: oai:DiVA.org:gih-403DiVA, id: diva2:768
Tilgjengelig fra: 2008-06-04 Laget: 2008-06-04 Sist oppdatert: 2018-01-11bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Seger, JanThorstensson, Alf

Søk i DiVA

Av forfatter/redaktør
Seger, JanThorstensson, Alf
Av organisasjonen
I samme tidsskrift
Acta Physiologica Scandinavica

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 104 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf