Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Coupling between 3D displacements and rotations at the glenohumeral joint during dynamic tasks in healthy participants.
Gymnastik- och idrottshögskolan, GIH, Institutionen för idrotts- och hälsovetenskap, Laboratoriet för biomekanik och motorisk kontroll (BMC).ORCID-id: 0000-0002-1210-6449
Vise andre og tillknytning
2014 (engelsk)Inngår i: Clinical Biomechanics, ISSN 0268-0033, E-ISSN 1879-1271, Vol. 29, nr 9, s. 1048-1055Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: Glenohumeral displacements assessment would help to design shoulder prostheses with physiological arthrokinematics and to establish more biofidelic musculoskeletal models. Though displacements were documented during static tasks, there is little information on their 3D coupling with glenohumeral angle during dynamic tasks. Our objective was to characterize the 3D glenohumeral displacement-rotation couplings during dynamic arm elevations and rotations.

METHODS: Glenohumeral displacements were measured from trajectories of reflective markers fitted on intracortical pins inserted into the scapula and humerus. Bone geometry was recorded using CT-scan. Only four participants were recruited to the experiment due to its invasiveness. Participants performed dynamic arm abduction, flexion and axial rotations. Linear regressions were performed between glenohumeral displacements and rotations. The pin of the scapula of one participant moved, his data were removed from analysis, and results are based on three participants.

FINDINGS: The measurement error of glenohumeral kinematics was less than 0.15mm and 0.2°. Maximum glenohumeral displacements were measured along the longitudinal direction and reached up to +12.4mm for one participant. Significant couplings were reported especially between longitudinal displacement and rotation in abduction (adjusted R(2) up to 0.94).

INTERPRETATION: The proposed method provides the potential to investigate glenohumeral kinematics during all kinds of movements. A linear increase of upward displacement during dynamic arm elevation was measured, which contrasts with results based on a series of static poses. The systematic investigation of glenohumeral displacements under dynamic condition may help to provide relevant recommendation for the design of shoulder prosthetic components and musculoskeletal models.

sted, utgiver, år, opplag, sider
2014. Vol. 29, nr 9, s. 1048-1055
HSV kategori
Forskningsprogram
Medicin/Teknik
Identifikatorer
URN: urn:nbn:se:gih:diva-3559DOI: 10.1016/j.clinbiomech.2014.08.006PubMedID: 25217235OAI: oai:DiVA.org:gih-3559DiVA, id: diva2:763954
Tilgjengelig fra: 2014-11-17 Laget: 2014-11-17 Sist oppdatert: 2017-12-05bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Arndt, Anton

Søk i DiVA

Av forfatter/redaktør
Arndt, Anton
Av organisasjonen
I samme tidsskrift
Clinical Biomechanics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 341 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf