Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Trunk muscle strength during constant velocity movements.
Gymnastik- och idrottshögskolan, GIH, Institutionen för idrotts- och hälsovetenskap, Laboratoriet för biomekanik och motorisk kontroll (BMC).
Gymnastik- och idrottshögskolan, GIH, Institutionen för idrotts- och hälsovetenskap, Laboratoriet för biomekanik och motorisk kontroll (BMC).ORCID-id: 0000-0002-3612-449X
1982 (engelsk)Inngår i: Scandinavian Journal of Rehabilitation Medicine, ISSN 0036-5505, E-ISSN 1940-2228, Vol. 14, nr 2, s. 61-8Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A new apparatus has been designed for standardized measurements of the strength of human trunk muscles utilizing the isokinetic (constant movement velocity) technique (Cybex). It is possible to measure the produced torque during maximal voluntary isometric and isokinetic contractions in the whole range of motion during flexion, extension and lateral flexion of the trunk. Effects of gravity are eliminated since the movements are performed in the horizontal plane. Torque can be measured around different centres of rotation of the body. With this experimental set-up the strength of the trunk muscles has been characterized in a group of 14 normal male subjects (18-31 yrs). The torque produced by the trunk muscles varied with movement velocity and trunk position in the arc of motion. Peak torque occurred in a position where the muscles involved were stretched. The strength of the trunk extensors exceeded that of the flexors, but the degree (ratio) varied with trunk position. The relative contribution of the hip muscles to the total torque produced with the centre of rotation at the hip joint was larger for flexors than for extensors and varied with velocity and position. It is concluded that the present technique is useful to characterize the human trunk muscles.

sted, utgiver, år, opplag, sider
1982. Vol. 14, nr 2, s. 61-8
Identifikatorer
URN: urn:nbn:se:gih:diva-599PubMedID: 7100831OAI: oai:DiVA.org:gih-599DiVA, id: diva2:173756
Tilgjengelig fra: 2009-02-17 Laget: 2009-02-16 Sist oppdatert: 2017-12-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

PubMed

Personposter BETA

Thorstensson, AlfNilsson, Johnny

Søk i DiVA

Av forfatter/redaktør
Thorstensson, AlfNilsson, Johnny
Av organisasjonen
I samme tidsskrift
Scandinavian Journal of Rehabilitation Medicine

Søk utenfor DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetric

pubmed
urn-nbn
Totalt: 107 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf