Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison between single and combined data collection methods in loaded squat jump power output
Gymnastik- och idrottshögskolan, GIH, Institutionen för idrotts- och hälsovetenskap, Åstrandlaboratoriet, Forskningsgruppen Mitokondriell funktion och metabolisk kontroll.ORCID-id: 0000-0002-8607-550X
Aspire Academy, Doha, Qatar.
Gymnastik- och idrottshögskolan, GIH, Institutionen för idrotts- och hälsovetenskap, Laboratoriet för tillämpad idrottsvetenskap (LTIV). University of Dalarna, Falun.ORCID-id: 0000-0002-3612-449X​
2017 (engelsk)Inngår i: Gazzetta Medica Italiana, ISSN 0393-3660, E-ISSN 1827-1812, Vol. 176, nr 6, s. 315-321Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: The aim of this study was to compare linear position transducer force plate-based methods and more complex combinations of those for calculation of power output in loaded squat jump.

METHODS: Eight methods were used simultaneously in data collection: vertical ground reaction force (VGRF), ground reaction forces (GRF), 1 linear position transducer (1LPT), 1LPT and VGRF (1LPT+VGRF), 2 linear position transducers (2LPTs), 2LPTs and VGRF (2LPTs+VGRF), 5 linear position transducers (5LPTs), 5LPTs and GRF (5LPTs+GRF). Power output was calculated for each lift according to the sensor or sensors used and the results were compared.

RESULTS: Power output calculated separately with LPTs and GRF method did not differ significantly from combined methods such as 1LPT+VGRF, 2LPTs+VGRF. No significant differences were found when comparing power output between 5LPTs+GRF and combined methods such as 2LPTs+VGRF.

CONCLUSIONS: This study indicates that test methodology with a simple single linear position transducer setup and or force platform suffice when recording vertical jump such as loaded squat jump.

sted, utgiver, år, opplag, sider
2017. Vol. 176, nr 6, s. 315-321
HSV kategori
Forskningsprogram
Medicin/Teknik
Identifikatorer
URN: urn:nbn:se:gih:diva-4909DOI: 10.23736/S0393-3660.16.03378-7ISI: 000404726300001OAI: oai:DiVA.org:gih-4909DiVA, id: diva2:1106368
Tilgjengelig fra: 2017-06-07 Laget: 2017-06-07 Sist oppdatert: 2017-09-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Cardinale, Daniele A.Nilsson, Johnny E.
Av organisasjonen
I samme tidsskrift
Gazzetta Medica Italiana

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 489 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf